{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-9039","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2026-05-19T16:54:40.242Z","datePublished":"2026-05-28T19:07:09.065Z","dateUpdated":"2026-05-29T15:01:35.931Z"},"containers":{"cna":{"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2026-05-28T19:07:09.065Z"},"title":"Initialization of a resource with an insecure default in XCharge C6","problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-1188","description":"CWE-1188 Initialization of a resource with an insecure default","type":"CWE"}]}],"affected":[{"vendor":"XCharge","product":"C6","versions":[{"status":"affected","version":"0","lessThan":"May_22_2026","versionType":"custom"}],"defaultStatus":"unaffected"}],"descriptions":[{"lang":"en","value":"A configuration weakness in the device’s remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access.","supportingMedia":[{"type":"text/html","base64":false,"value":"A configuration weakness in the device’s remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access."}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-148-08","tags":["government-resource"]}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"PHYSICAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"HIGH","baseScore":8.6,"vectorString":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"}}],"solutions":[{"lang":"en","value":"XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact","supportingMedia":[{"type":"text/html","base64":false,"value":"XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact"}]}],"credits":[{"lang":"en","value":"Lionel R. Saposnik of SaiFlow reported these vulnerabilities to CISA.","type":"finder"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.2"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-05-29T15:01:22.036193Z","id":"CVE-2026-9039","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-05-29T15:01:35.931Z"}}]}}