{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-86295","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2026-09-06T16:08:01.864Z","datePublished":"2026-09-07T10:15:09.161Z","dateUpdated":"2026-09-08T15:46:57.891Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2026-09-07T10:15:09.161Z"},"title":"D-Link DIR-895L udhcpcd serverpacket.c sendACK command injection","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-77","lang":"en","description":"Command Injection"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-74","lang":"en","description":"Injection"}]}],"affected":[{"vendor":"D-Link","product":"DIR-895L","versions":[{"version":"A1_102b07","status":"affected"}],"cpes":["cpe:2.3:h:d-link:dir-895l:*:*:*:*:*:*:*:*"],"modules":["udhcpcd"]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in D-Link DIR-895L A1_102b07. This affects the function sendACK of the file udhcpcd/serverpacket.c of the component udhcpcd. The manipulation of the argument Hostname results in command injection. The attack can be executed remotely. The exploit has been made public and could be used."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":6.9,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P","baseSeverity":"MEDIUM"}},{"cvssV3_1":{"version":"3.1","baseScore":8.3,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.3,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":7.5,"vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR"}}],"timeline":[{"time":"2026-09-06T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2026-09-06T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2026-09-06T18:13:07.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"tian (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/vuln/399457","name":"VDB-399457 | D-Link DIR-895L udhcpcd serverpacket.c sendACK command injection","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/vuln/399457/cti","name":"VDB-399457 | CTI Indicators (IOB, IOC, TTP, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/cve/CVE-2026-86295","name":"CVE-2026-86295 | CVE Analysis and Report","tags":["third-party-advisory"]},{"url":"https://vuldb.com/submit/906296","name":"Submit #906296 | D-Link DIR895LA1_102b07 A1_102b07 Command Injection","tags":["third-party-advisory"]},{"url":"https://tzh00203.notion.site/D-Link-DIR-895L-Command-Injection-in-udhcpd-sendACK-TR-069-Host-Helper-33cb5c52018a80aaaa5be16a761ff457","tags":["exploit"]},{"url":"https://www.dlink.com/","tags":["product"]}],"x_generator":["VulDB PVTS v202609"]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-09-08T15:46:49.246771Z","id":"CVE-2026-86295","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-09-08T15:46:57.891Z"}}]}}