{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-76701","assignerOrgId":"eb103674-0d28-4225-80f8-39fb86215de0","state":"PUBLISHED","assignerShortName":"hpe","dateReserved":"2026-08-19T16:12:09.681Z","datePublished":"2026-09-15T19:23:58.418Z","dateUpdated":"2026-09-21T19:54:31.017Z"},"containers":{"cna":{"affected":[{"defaultStatus":"affected","product":"EdgeConnect SD-WAN Gateways","vendor":"Hewlett Packard Enterprise (HPE)","versions":[{"lessThanOrEqual":"9.7.0.0","status":"affected","version":"9.7.0.0","versionType":"semver"},{"lessThanOrEqual":"9.6.3.1","status":"affected","version":"9.6.0.0","versionType":"semver"},{"lessThanOrEqual":"9.5.8.1","status":"affected","version":"9.5.0.0","versionType":"semver"},{"lessThanOrEqual":"9.4.8.2","status":"affected","version":"9.4.0.0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"reporter","value":"Internal security research (HPE Networking)."}],"descriptions":[{"lang":"en","value":"A vulnerability in the API endpoint of HPE Networking EdgeConnect SD-WAN Gateways could allow an unauthenticated remote attacker to access sensitive information. Successful exploitation could allow an attacker to retrieve information which could be used to potentially gain further access to network services supported by HPE Networking EdgeConnect SD-WAN Gateways."}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","baseScore":5.9,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","availabilityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"providerMetadata":{"orgId":"eb103674-0d28-4225-80f8-39fb86215de0","shortName":"hpe","dateUpdated":"2026-09-15T19:23:58.418Z"},"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us&docLocale=en_US"}],"source":{"advisory":"HPESBNW05135","discovery":"INTERNAL"},"title":"Unauthenticated Sensitive Information Disclosure in HPE Networking EdgeConnect SD-WAN Gateways","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-306","lang":"en","description":"CWE-306 Missing Authentication for Critical Function"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-09-21T19:54:11.087829Z","id":"CVE-2026-76701","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-09-21T19:54:31.017Z"}}]}}