{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-57023","assignerOrgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","state":"PUBLISHED","assignerShortName":"juniper","dateReserved":"2026-06-23T16:27:00.248Z","datePublished":"2026-07-09T21:06:34.219Z","dateUpdated":"2026-07-10T15:28:45.274Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","platforms":["SRX Series","MX Series with SPC3"],"product":"Junos OS","vendor":"Juniper Networks","versions":[{"lessThan":"23.4R2-S7","status":"affected","version":"23.4","versionType":"custom"},{"lessThan":"24.2R2-S4","status":"affected","version":"24.2","versionType":"custom"},{"lessThan":"24.4R2-S3","status":"affected","version":"24.4","versionType":"custom"},{"lessThan":"25.2R2","status":"affected","version":"25.2","versionType":"custom"}]}],"datePublic":"2026-07-08T16:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An Improper Validation of Specified Quantity in Input vulnerability in the TCP proxy plugin of Juniper Networks Junos OS on MX Series with SPC3, and SRX Series allows an unauthenticated, network-based attacker to cause a complete Denial of Service (DoS).<br><br>When TCP proxy is engaged in a flow session, to support ALGs,&nbsp;Advanced Anti-Malware, ICAP&nbsp;or UTM, a TCP packet with specifically malformed TCP header will cause flow processing daemon (flowd) to crash and restart. This causes a complete service outage until the system has automatically recovered.<br>\n\n<br><p>This issue affects Junos OS on MX with SPC3, and SRX Series:&nbsp;</p><p></p><ul><li>23.4 versions before 23.4R2-S7,&nbsp;</li><li>24.2 versions before 24.2R2-S4,&nbsp;</li><li>24.4 versions before 24.4R2-S3,</li><li>25.2 versions before 25.2R2.</li></ul><p></p><p>This issue does not affect releases before 23.4R1.</p>"}],"value":"An Improper Validation of Specified Quantity in Input vulnerability in the TCP proxy plugin of Juniper Networks Junos OS on MX Series with SPC3, and SRX Series allows an unauthenticated, network-based attacker to cause a complete Denial of Service (DoS).\n\nWhen TCP proxy is engaged in a flow session, to support ALGs, Advanced Anti-Malware, ICAP or UTM, a TCP packet with specifically malformed TCP header will cause flow processing daemon (flowd) to crash and restart. This causes a complete service outage until the system has automatically recovered.\n\n\n\nThis issue affects Junos OS on MX with SPC3, and SRX Series: \n\n\n\n  *  23.4 versions before 23.4R2-S7, \n  *  24.2 versions before 24.2R2-S4, \n  *  24.4 versions before 24.4R2-S3,\n  *  25.2 versions before 25.2R2.\n\n\n\n\nThis issue does not affect releases before 23.4R1."}],"exploits":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"Automatable":"YES","Recovery":"AUTOMATIC","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:A/RE:M","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"MODERATE"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-1284","description":"CWE-1284 Improper Validation of Specified Quantity in Input","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","shortName":"juniper","dateUpdated":"2026-07-09T21:06:34.219Z"},"references":[{"tags":["vendor-advisory"],"url":"https://supportportal.juniper.net/JSA110083"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The following software releases have been updated to resolve this specific issue: 23.4R2-S7, 24.2R2-S4, 24.4R2-S3, 25.2R2, 25.4R1, and all subsequent releases."}],"value":"The following software releases have been updated to resolve this specific issue: 23.4R2-S7, 24.2R2-S4, 24.4R2-S3, 25.2R2, 25.4R1, and all subsequent releases."}],"source":{"advisory":"JSA110083","defect":["1918795"],"discovery":"USER"},"title":"Junos OS: MX with SPC3, SRX Series: A specifically malformed TCP packet causes a flowd crash","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"There are no known workarounds for this issue."}],"value":"There are no known workarounds for this issue."}],"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-07-10T15:28:39.605123Z","id":"CVE-2026-57023","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-07-10T15:28:45.274Z"}}]}}