{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-5611","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2026-04-05T15:29:48.130Z","datePublished":"2026-04-06T02:00:17.506Z","dateUpdated":"2026-04-07T02:59:09.689Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2026-04-06T02:00:17.506Z"},"title":"Belkin F9K1015 formCrossBandSwitch stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"Stack-based Buffer Overflow"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-119","lang":"en","description":"Memory Corruption"}]}],"affected":[{"vendor":"Belkin","product":"F9K1015","versions":[{"version":"1.00.10","status":"affected"}],"cpes":["cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Belkin F9K1015 1.00.10. This affects the function formCrossBandSwitch of the file /goform/formCrossBandSwitch. Performing a manipulation of the argument webpage results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR"}}],"timeline":[{"time":"2026-04-05T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2026-04-05T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2026-04-05T17:35:06.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"LtzHust (VulDB User)","type":"reporter"},{"lang":"en","value":"VulDB CNA Team","type":"coordinator"}],"references":[{"url":"https://vuldb.com/vuln/355402","name":"VDB-355402 | Belkin F9K1015 formCrossBandSwitch stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/vuln/355402/cti","name":"VDB-355402 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/submit/785538","name":"Submit #785538 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_5/README.md","tags":["exploit"]}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-04-07T02:58:23.395786Z","id":"CVE-2026-5611","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-04-07T02:59:09.689Z"}}]}}