{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-22280","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","state":"PUBLISHED","assignerShortName":"dell","dateReserved":"2026-01-07T07:17:24.536Z","datePublished":"2026-01-22T19:01:11.528Z","dateUpdated":"2026-01-22T19:23:20.602Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerScale OneFS","vendor":"Dell","versions":[{"lessThan":"9.13.0.0","status":"affected","version":"N/A","versionType":"semver"},{"lessThan":"9.5.1.6","status":"affected","version":"N/A","versionType":"semver"},{"lessThan":"9.7.1.11","status":"affected","version":"N/A","versionType":"semver"},{"lessThan":"9.10.1.4","status":"affected","version":"N/A","versionType":"semver"}]}],"datePublic":"2026-01-22T18:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell PowerScale OneFS, versions 9.5.0.0 through 9.5.1.5, versions 9.6.0.0 through 9.7.1.10, versions 9.8.0.0 through 9.10.1.3, versions starting from 9.11.0.0 and prior to 9.13.0.0, contains an incorrect permission assignment for critical resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to denial of service.<br>"}],"value":"Dell PowerScale OneFS, versions 9.5.0.0 through 9.5.1.5, versions 9.6.0.0 through 9.7.1.10, versions 9.8.0.0 through 9.10.1.3, versions starting from 9.11.0.0 and prior to 9.13.0.0, contains an incorrect permission assignment for critical resource vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to denial of service."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-732","description":"CWE-732: Incorrect Permission Assignment for Critical Resource","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell","dateUpdated":"2026-01-22T19:01:11.528Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000415586/dsa-2026-049-security-update-for-dell-powerscale-onefs-multiple-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-01-22T19:22:59.352494Z","id":"CVE-2026-22280","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-01-22T19:23:20.602Z"}}]}}