{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2026-1772","assignerOrgId":"e383dce4-0c27-4495-91c4-0db157728d17","state":"PUBLISHED","assignerShortName":"Hitachi Energy","dateReserved":"2026-02-02T16:28:53.742Z","datePublished":"2026-02-24T13:03:23.592Z","dateUpdated":"2026-02-28T02:19:01.092Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"RTU500 series CMU firmware","vendor":"Hitachi Energy","versions":[{"lessThanOrEqual":"12.7.7","status":"affected","version":"12.7.1","versionType":"custom"},{"lessThanOrEqual":"13.5.4","status":"affected","version":"13.5.1","versionType":"custom"},{"lessThanOrEqual":"13.6.2","status":"affected","version":"13.6.1","versionType":"custom"},{"lessThanOrEqual":"13.7.7","status":"affected","version":"13.7.1","versionType":"custom"},{"status":"affected","version":"13.8.1","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.<br>"}],"value":"RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges."}],"impacts":[{"capecId":"CAPEC-503","descriptions":[{"lang":"en","value":"CAPEC-503 WebView Exposure"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":5.3,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-280","description":"CWE-280 Improper Handling of Insufficient Permissions or Privileges","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"e383dce4-0c27-4495-91c4-0db157728d17","shortName":"Hitachi Energy","dateUpdated":"2026-02-24T13:38:30.521Z"},"references":[{"url":"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000237&LanguageCode=en&DocumentPartId=&Action=Launch"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-02-28T02:18:35.605096Z","id":"CVE-2026-1772","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-02-28T02:19:01.092Z"}}]}}