{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-9063","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2025-08-15T12:55:33.964Z","datePublished":"2025-10-14T12:20:39.318Z","dateUpdated":"2025-10-14T18:45:57.209Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PanelView Plus 7 Performance Series B","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"V14.00"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">An authentication bypass security issue exists within FactoryTalk View Machine Edition  Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more. </span><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;</span>"}],"value":"An authentication bypass security issue exists within FactoryTalk View Machine Edition  Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":7,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"LOW","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-287","description":"CWE-287: Improper Authentication","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2025-10-14T12:20:39.318Z"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">PanelView Plus 7 </span><span style=\"background-color: rgb(255, 255, 255);\">Performance Series B</span> <a target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112&amp;mode=3&amp;refSoft=1&amp;versions=61168\">V14.103</a>"}],"value":"PanelView Plus 7 Performance Series B  V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx"}],"source":{"advisory":"SD1753","discovery":"INTERNAL"},"title":"Rockwell Automation PanelView Plus 7 Performance Series B Authentication Bypass","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-10-14T18:45:42.455090Z","id":"CVE-2025-9063","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-10-14T18:45:57.209Z"}}]}}