{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-7549","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2025-07-12T17:16:57.184Z","datePublished":"2025-07-13T22:44:06.676Z","dateUpdated":"2025-07-14T13:55:07.574Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2025-07-13T22:44:06.676Z"},"title":"Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"Stack-based Buffer Overflow"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-119","lang":"en","description":"Memory Corruption"}]}],"affected":[{"vendor":"Tenda","product":"FH1201","versions":[{"version":"1.2.0.14(408)","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."},{"lang":"de","value":"Eine kritische Schwachstelle wurde in Tenda FH1201 1.2.0.14(408) gefunden. Dies betrifft die Funktion frmL7ProtForm der Datei /goform/L7Prot. Durch Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk passieren. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR"}}],"timeline":[{"time":"2025-07-12T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2025-07-12T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2025-07-12T19:22:12.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"panda_0xf1 (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.316247","name":"VDB-316247 | Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.316247","name":"VDB-316247 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.614973","name":"Submit #614973 | Tenda FH1201 V1.2.0.14(408) Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md","tags":["related"]},{"url":"https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"references":[{"url":"https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc","tags":["exploit"]},{"url":"https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md","tags":["exploit"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-07-14T13:55:01.694988Z","id":"CVE-2025-7549","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-07-14T13:55:07.574Z"}}]}}