{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-6965","assignerOrgId":"14ed7db2-1595-443d-9d34-6215bf890778","state":"PUBLISHED","assignerShortName":"Google","dateReserved":"2025-07-01T09:19:04.750Z","datePublished":"2025-07-15T13:44:00.784Z","dateUpdated":"2026-04-29T03:55:46.708Z"},"containers":{"cna":{"affected":[{"collectionURL":"https://www.sqlite.org/src","defaultStatus":"unaffected","packageName":"expr.c","product":"SQLite","programFiles":["expr.c"],"vendor":"SQLite","versions":[{"lessThan":"3.50.2","status":"affected","version":"0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Vlad Stolyarov of Google's Threat Analysis Group, with assistance from Google Big Sleep"}],"datePublic":"2025-06-27T22:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above."}],"value":"There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above."}],"impacts":[{"capecId":"CAPEC-679","descriptions":[{"lang":"en","value":"CAPEC-679 Exploitation of Improperly Configured or Implemented Memory Protections"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NO","Recovery":"USER","Safety":"NEGLIGIBLE","attackComplexity":"HIGH","attackRequirements":"PRESENT","attackVector":"NETWORK","baseScore":7.2,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"GREEN","subAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"DIFFUSE","vectorString":"CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:L/VI:H/VA:L/SC:L/SI:H/SA:L/S:N/AU:N/R:U/V:D/RE:L/U:Green","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"LOW"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-197","description":"CWE-197: Numeric Truncation Error","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"14ed7db2-1595-443d-9d34-6215bf890778","shortName":"Google","dateUpdated":"2025-07-15T13:44:00.784Z"},"references":[{"url":"https://www.sqlite.org/src/info/5508b56fd24016c13981ec280ecdd833007c9d8dd595edb295b984c2b487b5c8"}],"source":{"discovery":"UNKNOWN"},"title":"Integer Truncation on SQLite","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-04-28T00:00:00+00:00","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3","id":"CVE-2025-6965"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-04-29T03:55:46.708Z"}},{"title":"CVE Program Container","references":[{"url":"http://seclists.org/fulldisclosure/2025/Sep/57"},{"url":"http://seclists.org/fulldisclosure/2025/Sep/56"},{"url":"http://seclists.org/fulldisclosure/2025/Sep/53"},{"url":"http://seclists.org/fulldisclosure/2025/Sep/58"},{"url":"http://seclists.org/fulldisclosure/2025/Sep/49"},{"url":"http://www.openwall.com/lists/oss-security/2025/09/06/1"}],"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2025-11-04T21:14:51.528Z"}},{"x_adpType":"supplier","providerMetadata":{"orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP","dateUpdated":"2026-04-14T08:58:07.313Z"},"affected":[{"vendor":"Siemens","product":"RUGGEDCOM CROSSBOW Station Access Controller (SAC)","versions":[{"status":"affected","version":"0","lessThan":"V5.8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIDIS Prime","versions":[{"status":"affected","version":"0","lessThan":"V4.0.800","versionType":"custom"}],"defaultStatus":"unknown"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-485750.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-225816.html"}]}]}}