{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-5608","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2025-06-04T10:51:42.326Z","datePublished":"2025-06-04T20:00:21.750Z","dateUpdated":"2025-06-04T20:47:43.871Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2025-06-04T20:00:21.750Z"},"title":"Tenda AC18 SetSysAutoRebbotCfg formsetreboottimer buffer overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-120","lang":"en","description":"Buffer Overflow"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-119","lang":"en","description":"Memory Corruption"}]}],"affected":[{"vendor":"Tenda","product":"AC18","versions":[{"version":"15.03.05.05","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."},{"lang":"de","value":"Es wurde eine kritische Schwachstelle in Tenda AC18 15.03.05.05 entdeckt. Betroffen hiervon ist die Funktion formsetreboottimer der Datei /goform/SetSysAutoRebbotCfg. Durch die Manipulation des Arguments rebootTime mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2025-06-04T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2025-06-04T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2025-06-04T12:56:53.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_tutu (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.311094","name":"VDB-311094 | Tenda AC18 SetSysAutoRebbotCfg formsetreboottimer buffer overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.311094","name":"VDB-311094 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.588935","name":"Submit #588935 | Tenda AC18 V15.03.05.05 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://lavender-bicycle-a5a.notion.site/Tenda-AC18-formsetreboottimer-20653a41781f801ab9e2e022dd089d69?source=copy_link","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-06-04T20:47:37.175736Z","id":"CVE-2025-5608","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-06-04T20:47:43.871Z"}}]}}