{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-5571","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2025-06-03T20:35:56.498Z","datePublished":"2025-06-04T05:31:53.898Z","dateUpdated":"2025-06-04T13:24:36.159Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2025-06-04T05:31:53.898Z"},"title":"D-Link DCS-932L setSystemAdmin os command injection","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-78","lang":"en","description":"OS Command Injection"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-77","lang":"en","description":"Command Injection"}]}],"affected":[{"vendor":"D-Link","product":"DCS-932L","versions":[{"version":"2.18.01","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."},{"lang":"de","value":"Es wurde eine kritische Schwachstelle in D-Link DCS-932L 2.18.01 ausgemacht. Dabei betrifft es die Funktion setSystemAdmin der Datei /setSystemAdmin. Durch die Manipulation des Arguments AdminID mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":5.3,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","baseSeverity":"MEDIUM"}},{"cvssV3_1":{"version":"3.1","baseScore":6.3,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","baseSeverity":"MEDIUM"}},{"cvssV3_0":{"version":"3.0","baseScore":6.3,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","baseSeverity":"MEDIUM"}},{"cvssV2_0":{"version":"2.0","baseScore":6.5,"vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P"}}],"timeline":[{"time":"2025-06-03T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2025-06-03T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2025-06-03T22:41:09.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"pjqwudi (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.311028","name":"VDB-311028 | D-Link DCS-932L setSystemAdmin os command injection","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.311028","name":"VDB-311028 | CTI Indicators (IOB, IOC, TTP, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.588465","name":"Submit #588465 | D-Link DCS932L 2.18.01 OS Command Injection","tags":["third-party-advisory"]},{"url":"https://github.com/wudipjq/my_vuln/blob/main/D-Link5/vuln_42/42.md","tags":["exploit"]},{"url":"https://www.dlink.com/","tags":["product"]}],"tags":["unsupported-when-assigned"]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-06-04T13:24:13.060208Z","id":"CVE-2025-5571","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-06-04T13:24:36.159Z"}}]}}