{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-54926","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2025-08-01T04:38:47.036Z","datePublished":"2025-08-20T13:48:02.393Z","dateUpdated":"2025-08-20T17:21:50.700Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Monitoring Expert (PME)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2022"},{"status":"affected","version":"Version 2023"},{"status":"affected","version":"Version 2024"},{"status":"affected","version":"Version 2024 R2"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2022 w/ Advanced Reporting Module"},{"status":"affected","version":"Version 2024 w/ Advanced Reporting Module"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed."}],"value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-22","description":"CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2025-08-20T13:48:02.393Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-224-02.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-08-20T17:21:43.158876Z","id":"CVE-2025-54926","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-08-20T17:21:50.700Z"}}]}}