{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-4809","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2025-05-16T08:44:09.877Z","datePublished":"2025-05-16T20:00:14.307Z","dateUpdated":"2025-05-17T02:29:55.165Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2025-05-16T20:00:14.307Z"},"title":"Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"Stack-based Buffer Overflow"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-119","lang":"en","description":"Memory Corruption"}]}],"affected":[{"vendor":"Tenda","product":"AC7","versions":[{"version":"15.03.06.44","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."},{"lang":"de","value":"Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Betroffen hiervon ist die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterCfg. Durch Beeinflussen des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2025-05-16T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2025-05-16T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2025-05-16T10:49:17.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_miemie (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.309264","name":"VDB-309264 | Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.309264","name":"VDB-309264 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.573642","name":"Submit #573642 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromSafeSetMacFilter-1ed53a41781f80cbbf13c8d4cc405ed1?pvs=4","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-05-17T02:29:39.364436Z","id":"CVE-2025-4809","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-05-17T02:29:55.165Z"}}]}}