{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-41660","assignerOrgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","state":"PUBLISHED","assignerShortName":"CERTVDE","dateReserved":"2025-04-16T11:17:48.307Z","datePublished":"2026-03-24T07:41:43.004Z","dateUpdated":"2026-03-24T13:16:02.920Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"CODESYS Control RTE (SL)","vendor":"CODESYS","versions":[{"lessThan":"3.5.22.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control RTE (for Beckhoff CX) SL","vendor":"CODESYS","versions":[{"lessThan":"3.5.22.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control Win (SL)","vendor":"CODESYS","versions":[{"lessThan":"3.5.22.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS HMI (SL)","vendor":"CODESYS","versions":[{"lessThan":"3.5.22.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Runtime Toolkit","vendor":"CODESYS","versions":[{"lessThan":"3.5.22.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for BeagleBone SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for emPC-A/iMX6 SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for IOT2000 SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for Linux ARM SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for Linux SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for PFC100 SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for PFC200 SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for PLCnext SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for Raspberry Pi SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Control for WAGO Touch Panels 600 SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"CODESYS Virtual Control SL","vendor":"CODESYS","versions":[{"lessThan":"4.21.0.0","status":"affected","version":"0.0.0","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","user":"00000000-0000-4000-9000-000000000000","value":"Luca Borzacchiello from Nozomi Networks"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.<br>"}],"value":"A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-669","description":"CWE-669 Incorrect Resource Transfer Between Spheres","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"270ccfa6-a436-4e77-922e-914ec3a9685c","shortName":"CERTVDE","dateUpdated":"2026-03-24T07:41:43.004Z"},"references":[{"url":"https://certvde.com/de/advisories/VDE-2026-011"}],"source":{"advisory":"VDE-2026-011","defect":["CERT@VDE#641802"],"discovery":"UNKNOWN"},"title":"CODESYS Control Boot Application Replacement Enables Code Execution","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-03-24T13:15:49.570572Z","id":"CVE-2025-41660","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-03-24T13:16:02.920Z"}}]}}