{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-41224","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2025-04-16T09:27:14.282Z","datePublished":"2025-07-08T10:35:09.492Z","dateUpdated":"2025-07-08T20:31:27.395Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2025-07-08T10:35:09.492Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.10.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RSL910NC (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected products do not properly enforce interface access restrictions when changing from management to non-management interface configurations until a system reboot occurs, despite configuration being saved. This could allow an attacker with network access and credentials to gain access to device through non-management and maintain SSH access to the device until reboot."}],"affected":[{"vendor":"Siemens","product":"RUGGEDCOM RMC8388 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RMC8388NC V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS416NCv2 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS416PNCv2 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS416Pv2 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS416v2 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS900 (32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS900G (32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS900GNC(32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RS900NC(32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100 (32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100NC(32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100P (32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2100PNC (32M) V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2288 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2288NC V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300NC V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300P V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2300PNC V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2488 V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG2488NC V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG907R","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG908C","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG909R","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG910C","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG920P V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSG920PNC V5.X","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSL910","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RSL910NC","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RST2228","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RST2228P","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RST916C","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RST916P","versions":[{"status":"affected","version":"0","lessThan":"V5.10.0","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":7.7,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-693","description":"CWE-693: Protection Mechanism Failure","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-083019.html"}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-07-08T20:31:21.314188Z","id":"CVE-2025-41224","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-07-08T20:31:27.395Z"}}]}}