{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-41004","assignerOrgId":"0cbda920-cd7f-484a-8e76-bf7f4b7f4516","state":"PUBLISHED","assignerShortName":"INCIBE","dateReserved":"2025-04-16T09:08:41.550Z","datePublished":"2026-01-12T13:55:28.273Z","dateUpdated":"2026-01-12T14:20:07.352Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Patient Record Management System","vendor":"Imaster","versions":[{"status":"affected","version":"All versions"}]}],"credits":[{"lang":"en","type":"finder","value":"Gonzalo Aguilar García (6h4ack)"}],"datePublic":"2026-01-12T13:31:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Imaster's Patient Records Management System is vulnerable to SQL Injection in the endpoint ‘/projects/hospital/admin/complaints.php’ through the ‘id’ parameter."}],"value":"Imaster's Patient Records Management System is vulnerable to SQL Injection in the endpoint ‘/projects/hospital/admin/complaints.php’ through the ‘id’ parameter."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-89","description":"CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"0cbda920-cd7f-484a-8e76-bf7f4b7f4516","shortName":"INCIBE","dateUpdated":"2026-01-12T13:55:28.273Z"},"references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-imaster-products"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"No solution has been reported at this time.<br>"}],"value":"No solution has been reported at this time."}],"source":{"discovery":"EXTERNAL"},"title":"Multiple vulnerabilities in Imaster products Open configuration options","x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-01-12T14:19:59.030498Z","id":"CVE-2025-41004","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-01-12T14:20:07.352Z"}}]}}