{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-3128","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","state":"PUBLISHED","assignerShortName":"icscert","dateReserved":"2025-04-02T15:44:23.734Z","datePublished":"2025-08-21T19:37:28.430Z","dateUpdated":"2025-08-22T15:50:28.090Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"smartRTU","vendor":"Mitsubishi Electric Europe","versions":[{"lessThanOrEqual":"3.37","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Noam Moshe of Claroty Team82 reported this vulnerability to CISA."}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"A remote unauthenticated attacker who has bypassed authentication could \nexecute arbitrary OS commands to disclose, tamper with, destroy or \ndelete information in Mitsubishi Electric smartRTU, or cause a denial-of\n service condition on the product."}],"value":"A remote unauthenticated attacker who has bypassed authentication could \nexecute arbitrary OS commands to disclose, tamper with, destroy or \ndelete information in Mitsubishi Electric smartRTU, or cause a denial-of\n service condition on the product."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert","dateUpdated":"2025-08-21T19:38:21.586Z"},"references":[{"url":"https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-105-09"}],"source":{"advisory":"ICSA-25-105-09","discovery":"EXTERNAL"},"title":"Mitsubishi Electric Europe smartRTU OS Command Injection","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Mitsubishi Electric Europe B.V. recommends that users take note of \nthe following mitigation measures to minimize the risk of exploiting \nthis vulnerability:</p>\n<ul>\n<li>Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.</li>\n<li>Use within a LAN and block access from untrusted networks and hosts through firewalls.</li>\n<li>Use web application firewall (WAF) to prevent to filter, monitor and block any malicious HTTP/HTTPS traffic.</li>\n<li>Allow web client access from trusted networks only.</li>\n</ul><p>For more information, please see <a target=\"_blank\" rel=\"nofollow\" href=\"https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information\">Mitsubishi Electric Europe MEU_PSIRT_2025-3128</a>&nbsp;under the \"Vulnerability Information\" section.\n\n<br></p>"}],"value":"Mitsubishi Electric Europe B.V. recommends that users take note of \nthe following mitigation measures to minimize the risk of exploiting \nthis vulnerability:\n\n\n\n  *  Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.\n\n  *  Use within a LAN and block access from untrusted networks and hosts through firewalls.\n\n  *  Use web application firewall (WAF) to prevent to filter, monitor and block any malicious HTTP/HTTPS traffic.\n\n  *  Allow web client access from trusted networks only.\n\n\n\nFor more information, please see  Mitsubishi Electric Europe MEU_PSIRT_2025-3128 https://emea.mitsubishielectric.com/fa/products/quality/quality-news-information  under the \"Vulnerability Information\" section."}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-08-22T15:50:22.725717Z","id":"CVE-2025-3128","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-08-22T15:50:28.090Z"}}]}}