{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-30033","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2025-03-14T09:05:35.696Z","datePublished":"2025-08-12T11:16:56.565Z","dateUpdated":"2026-03-10T16:07:45.420Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2026-03-10T16:07:45.420Z"},"descriptions":[{"lang":"en","value":"The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component."}],"affected":[{"vendor":"Siemens","product":"Automation License Manager V6.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Automation License Manager V6.2","versions":[{"status":"affected","version":"0","lessThan":"V6.2 Upd3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"CEMAT V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"CP PtP Param configuring interface","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Create MyConfig (CMC)","versions":[{"status":"affected","version":"0","lessThan":"V6.9","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Energy Support Library (EnSL)","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"FM Configuration Package","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Modular PID CTRL Tool","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"MultiFieldbus Configuration Tool (MFCT)","versions":[{"status":"affected","version":"0","lessThan":"V1.5.5.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"OpenPCS 7 V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"OpenPCS 7 V9.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Siemens Network Planner (SINETPLAN)","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Automation Tool","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Automation Tool SDK Windows","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC BATCH V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC BATCH V9.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Control Function Library (CFL) V1.x","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Control Function Library (CFL) V2.x","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Control Function Library (CFL) V3.x","versions":[{"status":"affected","version":"0","lessThan":"V3.1.0.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Control Function Library (CFL) V4.x","versions":[{"status":"affected","version":"0","lessThan":"V4.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC D7-SYS","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC eaSie Core Package","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC eaSie Document Skills","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC eaSie PCS 7 Skill Package","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC eaSie Workflow Skills","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Energy Suite V17","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Energy Suite V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Energy Suite V19","versions":[{"status":"affected","version":"0","lessThan":"V19 Update 4","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Logon V1.6","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Logon V2.0","versions":[{"status":"affected","version":"0","lessThan":"V2.0 Upd3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Management Agent","versions":[{"status":"affected","version":"0","lessThan":"V9.1 SP1 Upd8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Management Console","versions":[{"status":"affected","version":"0","lessThan":"V9.1 SP1 Upd8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MTP CREATOR V2.x","versions":[{"status":"affected","version":"0","lessThan":"V2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MTP CREATOR V3.x","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MTP CREATOR V4.x","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MTP CREATOR V5.x","versions":[{"status":"affected","version":"0","lessThan":"V5.0.0.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MTP Integrator V1.x","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MTP Integrator V2.x","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC NET PC Software V16","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC NET PC Software V17","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC NET PC Software V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC NET PC Software V19","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC NET PC Software V20","versions":[{"status":"affected","version":"0","lessThan":"V20.0 Update 1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ODK 1500S","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Advanced Process Faceplates V9.1","versions":[{"status":"affected","version":"0","lessThan":"V9.1 SP2 Upd4","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Advanced Process Functions V2.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Advanced Process Functions V2.2","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Advanced Process Graphics V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Advanced Process Graphics V9.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Advanced Process Library V9.1","versions":[{"status":"affected","version":"0","lessThan":"V9.1 SP2 Upd6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Basis Faceplates V9.1","versions":[{"status":"affected","version":"0","lessThan":"V9.1 SP2 Upd2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Basis Library V10.0","versions":[{"status":"affected","version":"0","lessThan":"V10.0 SP1 Upd2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Basis Library V9.1","versions":[{"status":"affected","version":"0","lessThan":"V9.1 SP2 Upd8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Industry Library V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Industry Library V9.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Industry Library V9.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Logic Matrix V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Logic Matrix V9.1","versions":[{"status":"affected","version":"0","lessThan":"V9.1 Upd8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 MPC Configurator","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 PowerControl","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Standard Chemical Library V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 Standard Chemical Library V9.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 TeleControl","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 V10.0","versions":[{"status":"affected","version":"0","lessThan":"V10.0 SP1 UC01","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7 V9.1","versions":[{"status":"affected","version":"0","lessThan":"V9.1 SP1 UC08","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS 7/OPEN OS V9.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS neo V5.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PCS neo V6.0","versions":[{"status":"affected","version":"0","lessThan":"V6.0 SP1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PDM Maintenance Station V5.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PDM V9.2","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PDM V9.3","versions":[{"status":"affected","version":"0","lessThan":"V9.3 SP1 Upd2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Process Function Library (PFL) V4.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Process Historian 2020","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Process Historian 2022","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Process Historian 2024","versions":[{"status":"affected","version":"0","lessThan":"V2024 SP1 Upd2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ProSave V17","versions":[{"status":"affected","version":"0","lessThan":"V17 Update 9","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ProSave V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ProSave V19","versions":[{"status":"affected","version":"0","lessThan":"V19 Update 4","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ProSave V20","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Route Control V10.0","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Route Control V9.1","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7 F Systems V6.3","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7 F Systems V6.4","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller V2","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller V3","versions":[{"status":"affected","version":"0","lessThan":"V31.1.5","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)","versions":[{"status":"affected","version":"0","lessThan":"V4.0.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-PCT","versions":[{"status":"affected","version":"0","lessThan":"V3.5 SP4 Update 1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM Advanced","versions":[{"status":"affected","version":"0","lessThan":"V7.0 Update 1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM V17","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM V19","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-PLCSIM V20","versions":[{"status":"affected","version":"0","lessThan":"V20 Update 1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Safety Matrix","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC STEP 7 CFC V19","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC STEP 7 CFC V20","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC STEP 7 V5.7","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Target","versions":[{"status":"affected","version":"0","lessThan":"V6.0 SP3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC flexible ES","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Advanced","versions":[{"status":"affected","version":"0","lessThan":"V17 Update 9","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional","versions":[{"status":"affected","version":"0","lessThan":"V21","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Runtime Professional V20","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC TeleControl","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Unified Line Coordination","versions":[{"status":"affected","version":"0","lessThan":"V20","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Unified PC Runtime V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Unified PC Runtime V19","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Unified PC Runtime V20","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Unified Sequence","versions":[{"status":"affected","version":"0","lessThan":"V20","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC V7.5","versions":[{"status":"affected","version":"0","lessThan":"V7.5 SP2 Update 20","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC V8.0","versions":[{"status":"affected","version":"0","lessThan":"V8.0 Update 8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC V8.1","versions":[{"status":"affected","version":"0","lessThan":"V8.1 Update 3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Visualization Architect (SiVArc) V17","versions":[{"status":"affected","version":"0","lessThan":"V17 Update 9","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Visualization Architect (SiVArc) V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Visualization Architect (SiVArc) V19","versions":[{"status":"affected","version":"0","lessThan":"V19 Update 4","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinCC Visualization Architect (SiVArc) V20","versions":[{"status":"affected","version":"0","lessThan":"V20 Update 3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMIT Rapid Tester","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMIT Simulation Platform","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS Startdrive V17","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS Startdrive V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS Startdrive V19","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS Startdrive V20","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINEC NMS","versions":[{"status":"affected","version":"0","lessThan":"V4.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINEMA Remote Connect Client","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SITRANS","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Standard PID CTRL Tool","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Administrator","versions":[{"status":"affected","version":"0","lessThan":"V3.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Portal Cloud Connector","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Portal Test Suite V17","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Portal Test Suite V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Portal Test Suite V19","versions":[{"status":"affected","version":"0","lessThan":"V19 Update 4","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Portal Test Suite V20","versions":[{"status":"affected","version":"0","lessThan":"V20 Update 3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Project-Server","versions":[{"status":"affected","version":"0","lessThan":"V2.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TIA Project-Server V17","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V17","versions":[{"status":"affected","version":"0","lessThan":"V17 Update 9","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V18","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V19","versions":[{"status":"affected","version":"0","lessThan":"V19 Update 4","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Totally Integrated Automation Portal (TIA Portal) V20","versions":[{"status":"affected","version":"0","lessThan":"V20 Update 4","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"WinCC Panel Image Setup","versions":[{"status":"affected","version":"0","lessThan":"V17 Update 9","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":8.5,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-427","description":"CWE-427: Uncontrolled Search Path Element","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-282044.html"}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-08-12T20:10:10.615077Z","id":"CVE-2025-30033","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-08-12T20:10:30.205Z"}}]}}