{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-27261","assignerOrgId":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","state":"PUBLISHED","assignerShortName":"ERIC","dateReserved":"2025-02-21T08:58:20.367Z","datePublished":"2025-09-25T13:47:06.233Z","dateUpdated":"2025-09-30T12:12:39.842Z"},"containers":{"cna":{"affected":[{"defaultStatus":"affected","product":"Indoor Connect 8855","vendor":"Ericsson","versions":[{"changes":[{"at":"2025.Q2","status":"unaffected"}],"lessThan":"2025.Q2","status":"affected","version":"0","versionType":"Indoor Connect 8855"}]}],"credits":[{"lang":"en","type":"finder","value":"Telstra"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Ericsson Indoor Connect 8855 contains an SQL injection vulnerability which if exploited can result in unauthorized disclosure or modification of data.</span>"}],"value":"Ericsson Indoor Connect 8855 contains an SQL injection vulnerability which if exploited can result in unauthorized disclosure or modification of data."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-89","description":"CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","shortName":"ERIC","dateUpdated":"2025-09-30T12:12:39.842Z"},"references":[{"url":"https://www.ericsson.com/en/about-us/security/psirt/e2025-09-25"}],"source":{"discovery":"UNKNOWN"},"title":"Ericsson Indoor Connect 8855 - Improper Neutralization of Special Elements used in an SQL Command Vulnerability","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-09-25T14:30:26.479892Z","id":"CVE-2025-27261","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-09-25T14:30:40.991Z"}}]}}