{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-26336","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","state":"PUBLISHED","assignerShortName":"dell","dateReserved":"2025-02-07T06:04:04.738Z","datePublished":"2025-03-21T02:23:46.785Z","dateUpdated":"2025-03-21T13:59:49.924Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2","vendor":"Dell","versions":[{"lessThan":"2.40.200.202101130302","status":"affected","version":"N/A","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Dell Chassis Management Controller (CMC) for PowerEdge VRTX","vendor":"Dell","versions":[{"lessThan":"3.41.200.202209300499","status":"affected","version":"N/A","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Dell would like to thank Aliz Hammond of watchTowr for reporting these issues"}],"datePublic":"2025-03-20T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution.<br>"}],"value":"Dell Chassis Management Controller Firmware for Dell PowerEdge FX2, version(s) prior to 2.40.200.202101130302, and Dell Chassis Management Controller Firmware for Dell PowerEdge VRTX version(s) prior to 3.41.200.202209300499, contain(s) a Stack-based Buffer Overflow vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Remote execution."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","description":"CWE-121: Stack-based Buffer Overflow","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell","dateUpdated":"2025-03-21T02:23:46.785Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000297463/dsa-2025-123-security-update-for-dell-chassis-management-controller-firmware-for-dell-poweredge-fx2-and-vrtx-vulnerabilities"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-21T13:59:37.293545Z","id":"CVE-2025-26336","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-03-21T13:59:49.924Z"}}]}}