{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-24480","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2025-01-21T21:21:03.342Z","datePublished":"2025-01-28T19:01:41.484Z","dateUpdated":"2025-02-05T18:49:55.832Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"FactoryTalk® View Machine Edition","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"<V15"}]}],"datePublic":"2025-01-28T14:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user.</span>"}],"value":"A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user."}],"impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88: OS Command Injection"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2025-02-05T18:49:55.832Z"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1719.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Upgrade to V15.00 or apply patch in AID&nbsp;<span style=\"background-color: rgb(255, 255, 255);\">1152571</span>\n\n</span><br>"}],"value":"Upgrade to V15.00 or apply patch in AID 1152571"}],"source":{"discovery":"INTERNAL"},"title":"FactoryTalk® View Machine Editon - Remote Code Execution","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>Protect network access to the device &amp; s<span style=\"background-color: var(--wht);\">trictly constrain the parameters of invoked functions</span></p>\n\n<br>"}],"value":"Protect network access to the device & strictly constrain the parameters of invoked functions"}],"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-01-28T19:20:28.530752Z","id":"CVE-2025-24480","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-01-28T19:20:34.732Z"}}]}}