{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-23400","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2025-01-15T14:20:46.047Z","datePublished":"2025-03-11T09:48:15.383Z","dateUpdated":"2025-03-11T14:59:33.908Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2025-03-11T09:48:15.383Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."}],"affected":[{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","versions":[{"status":"affected","version":"0","lessThan":"V14.3.0.13","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2312","versions":[{"status":"affected","version":"0","lessThan":"V2312.0009","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2406","versions":[{"status":"affected","version":"0","lessThan":"V2406.0007","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2412","versions":[{"status":"affected","version":"0","lessThan":"V2412.0002","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","versions":[{"status":"affected","version":"0","lessThan":"V2302.0021","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2404","versions":[{"status":"affected","version":"0","lessThan":"V2404.0010","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":7.3,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-119","description":"CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-050438.html"}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-11T14:57:36.559116Z","id":"CVE-2025-23400","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-03-11T14:59:33.908Z"}}]}}