{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-22366","assignerOrgId":"b87402ff-ae37-4194-9dae-31abdbd6f217","state":"PUBLISHED","assignerShortName":"DIVD","dateReserved":"2025-01-03T14:56:05.685Z","datePublished":"2025-03-11T13:40:23.659Z","dateUpdated":"2025-04-01T04:47:47.110Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Smart / Premium charging stations","vendor":"Mennekes","versions":[{"lessThan":"2.15","status":"affected","version":"*","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Wilco van Beijnum"},{"lang":"en","type":"analyst","value":"Harm van den Brink(DIVD)"},{"lang":"en","type":"analyst","value":"Frank Breedijk (DIVD)"}],"datePublic":"2025-03-10T14:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.<br><br><br>"}],"value":"The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."}],"impacts":[{"capecId":"CAPEC-248","descriptions":[{"lang":"en","value":"CAPEC-248 Command Injection"}]}],"metrics":[{"cvssV4_0":{"Automatable":"YES","Recovery":"NOT_DEFINED","Safety":"NEGLIGIBLE","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"LOW","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]},{"descriptions":[{"cweId":"CWE-250","description":"CWE-250","lang":"en","type":"CWE"}]},{"descriptions":[{"description":"OWASP-A03","lang":"en"}]}],"providerMetadata":{"orgId":"b87402ff-ae37-4194-9dae-31abdbd6f217","shortName":"DIVD","dateUpdated":"2025-04-01T04:47:47.110Z"},"references":[{"tags":["third-party-advisory"],"url":"https://csirt.divd.nl/CVE-2025-22366"},{"tags":["vendor-advisory"],"url":"https://csirt.divd.nl/DIVD-2025-00003"},{"tags":["release-notes"],"url":"https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"}],"source":{"discovery":"EXTERNAL"},"title":"Mennekes smart/premium charges systems, Command injection in firmware upgrade","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-03-11T14:53:28.425309Z","id":"CVE-2025-22366","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-03-11T14:53:56.159Z"}}]}}