{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-15630","assignerOrgId":"f23511db-6c3e-4e32-a477-6aa17d310630","state":"PUBLISHED","assignerShortName":"TPLink","dateReserved":"2026-04-10T16:33:55.447Z","datePublished":"2026-08-03T17:51:06.542Z","dateUpdated":"2026-08-03T18:30:42.253Z"},"containers":{"cna":{"providerMetadata":{"orgId":"f23511db-6c3e-4e32-a477-6aa17d310630","shortName":"TPLink","dateUpdated":"2026-08-03T17:51:06.542Z"},"title":"Device Provisioning Race Condition in TP-Link Omada Adoption Workflow","problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-362","description":"CWE-362 Concurrent Execution using Shared Resource with Improper Synchronization","type":"CWE"}]}],"impacts":[{"capecId":"CAPEC-26","descriptions":[{"lang":"en","value":"CAPEC-26 Leveraging Race Conditions"}]}],"affected":[{"vendor":"TP-Link Systems Inc.","product":"Omada Gateways","versions":[{"status":"affected","version":"0","versionType":"custom"}],"defaultStatus":"unaffected"},{"vendor":"TP-Link Systems Inc.","product":"Omada Switches","versions":[{"status":"affected","version":"0","versionType":"custom"}],"defaultStatus":"unaffected"},{"vendor":"TP Link Systems Inc.","product":"Omada Access Points","versions":[{"status":"affected","version":"0","versionType":"custom"}],"defaultStatus":"unaffected"},{"vendor":"TP-Link Systems Inc","product":"Omada Controllers","versions":[{"status":"affected","version":"0","versionType":"custom"}],"defaultStatus":"unaffected"}],"descriptions":[{"lang":"en","value":"A race\ncondition exists in the cloud-based Omada device adoption process when an\nattacker may be able to interact with the adoption workflow before a legitimate\ndevice completes registration, resulting in provisioning information being\ndelivered to an attacker.\n\n\n\n\n\n\n\n\n\nSuccessful\nexploitation may allow disclosure of provisioning information intended for a\nlegitimate device.","supportingMedia":[{"type":"text/html","base64":false,"value":"<p>A race\ncondition exists in the cloud-based Omada device adoption process when an\nattacker may be able to interact with the adoption workflow before a legitimate\ndevice completes registration, resulting in provisioning information being\ndelivered to an attacker.</p><p>\n\n</p><p>Successful\nexploitation may allow disclosure of provisioning information intended for a\nlegitimate device.</p>"}]}],"references":[{"url":"https://www.omadanetworks.com/us/support/download/","tags":["patch"]},{"url":"https://www.omadanetworks.com/en/support/download/","tags":["patch"]},{"url":"https://www.tp-link.com/us/support/faq/5216/","tags":["vendor-advisory"]}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"HIGH","attackRequirements":"PRESENT","privilegesRequired":"LOW","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"LOW","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"LOW","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"MEDIUM","baseScore":5.8,"vectorString":"CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N"}}],"credits":[{"lang":"en","value":"Stanislav Dashevskyi and Francesco La Spina of Forescout Technologies","type":"finder"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 1.0.4"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-08-03T18:30:34.469336Z","id":"CVE-2025-15630","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-08-03T18:30:42.253Z"}}]}}