{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-15237","assignerOrgId":"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e","state":"PUBLISHED","assignerShortName":"twcert","dateReserved":"2025-12-29T08:08:03.541Z","datePublished":"2026-01-05T07:42:58.327Z","dateUpdated":"2026-01-05T21:10:36.302Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"QOCA aim AI Medical Cloud Platform","vendor":"Quanta Computer","versions":[{"lessThanOrEqual":"2.7.5","status":"affected","version":"0","versionType":"custom"}]}],"datePublic":"2026-01-05T07:40:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"QOCA aim AI Medical Cloud Platform developed by Quanta Computer has a Path Traversal vulnerability, allowing authenticated remote attackers to read folder names under the specified path by exploiting an Absolute Path Traversal vulnerability."}],"value":"QOCA aim AI Medical Cloud Platform developed by Quanta Computer has a Path Traversal vulnerability, allowing authenticated remote attackers to read folder names under the specified path by exploiting an Absolute Path Traversal vulnerability."}],"impacts":[{"capecId":"CAPEC-597","descriptions":[{"lang":"en","value":"CAPEC-597 Absolute Path Traversal"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":5.3,"baseSeverity":"MEDIUM","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-36","description":"CWE-36 Absolute Path Traversal","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e","shortName":"twcert","dateUpdated":"2026-01-05T07:42:58.327Z"},"references":[{"tags":["third-party-advisory"],"url":"https://www.twcert.org.tw/tw/cp-132-10615-157a3-1.html"},{"tags":["third-party-advisory"],"url":"https://www.twcert.org.tw/en/cp-139-10616-cd942-2.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Update to version v2.7.6 or later.<br>"}],"value":"Update to version v2.7.6 or later."}],"source":{"advisory":"TVN-202601001","discovery":"EXTERNAL"},"title":"Quanta Computer｜QOCA aim AI Medical Cloud Platform - Path Traversal","x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-01-05T21:10:27.418343Z","id":"CVE-2025-15237","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-01-05T21:10:36.302Z"}}]}}