{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-14823","assignerOrgId":"7d616e1a-3288-43b1-a0dd-0a65d3e70a49","state":"PUBLISHED","assignerShortName":"ConnectWise","dateReserved":"2025-12-17T11:56:55.302Z","datePublished":"2025-12-18T15:50:06.929Z","dateUpdated":"2025-12-18T16:04:17.893Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","modules":["ScreenConnect Certificate Signing Extension"],"product":"ScreenConnect","vendor":"ConnectWise","versions":[{"status":"affected","version":"ScreenConnect (all supported versions) when used with the Certificate Signing Extension versions prior to 1.0.12"}]}],"credits":[{"lang":"en","type":"finder","value":"Michael Gilliam (Dean Dorton Allen Ford, PLLC)"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"In deployments using the ScreenConnect™ Certificate Signing Extension, encrypted configuration values including an Azure Key Vault-related key, could be returned to unauthenticated users through a client-facing endpoint under certain conditions. The values remained encrypted and securely stored at rest; however, an encrypted representation could be exposed in client responses. Updating the Certificate Signing Extension to version 1.0.12 or higher ensures configuration handling occurs exclusively on the server side, preventing encrypted values from being transmitted to or rendered by client-side components."}],"value":"In deployments using the ScreenConnect™ Certificate Signing Extension, encrypted configuration values including an Azure Key Vault-related key, could be returned to unauthenticated users through a client-facing endpoint under certain conditions. The values remained encrypted and securely stored at rest; however, an encrypted representation could be exposed in client responses. Updating the Certificate Signing Extension to version 1.0.12 or higher ensures configuration handling occurs exclusively on the server side, preventing encrypted values from being transmitted to or rendered by client-side components."}],"impacts":[{"capecId":"CAPEC-118","descriptions":[{"lang":"en","value":"CAPEC-118 – Data Leakage"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-201","description":"CWE-201 Insertion of Sensitive Information Into Sent Data","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"7d616e1a-3288-43b1-a0dd-0a65d3e70a49","shortName":"ConnectWise","dateUpdated":"2025-12-18T15:50:06.929Z"},"references":[{"url":"https://www.connectwise.com/company/trust/security-bulletins/2025-12-18-screenconnect-certificate-signing-extension-update"}],"source":{"discovery":"UNKNOWN"},"title":"Certificate Signing Extension Returns Encrypted Values","x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-12-18T16:03:26.953690Z","id":"CVE-2025-14823","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-12-18T16:04:17.893Z"}}]}}