{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-13905","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2025-12-02T16:35:40.124Z","datePublished":"2026-01-29T15:20:45.864Z","dateUpdated":"2026-01-29T16:10:59.092Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"EcoStruxure™ Process Expert","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions prior to 2025"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Process Expert for AVEVA System Platform","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions"}]}],"datePublic":"2026-01-13T15:18:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause  privilege escalation through the reverse shell when  one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart."}],"value":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause  privilege escalation through the reverse shell when  one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":7,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-276","description":"CWE-276 Incorrect Default Permissions","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2026-01-29T15:20:45.864Z"},"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-02.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2026-01-29T15:50:11.436614Z","id":"CVE-2025-13905","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-01-29T16:10:59.092Z"}}]}}