{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-12995","assignerOrgId":"3c337f33-b2bd-4529-9792-f48cdb2838b4","state":"PUBLISHED","assignerShortName":"Medtronic","dateReserved":"2025-11-11T03:38:45.676Z","datePublished":"2025-12-04T20:03:00.854Z","dateUpdated":"2025-12-08T21:08:48.839Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"CareLink Network","vendor":"Medtronic","versions":[{"lessThan":"December 4, 2025","status":"affected","version":"0","versionType":"custom"}]}],"credits":[{"lang":"en","type":"finder","value":"Bernhard Lorenz"}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025."}],"value":"Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025."}],"impacts":[{"capecId":"CAPEC-49","descriptions":[{"lang":"en","value":"CAPEC-49 Password Brute Forcing"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-307","description":"CWE-307 Improper Restriction of Excessive Authentication Attempts","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"3c337f33-b2bd-4529-9792-f48cdb2838b4","shortName":"Medtronic","dateUpdated":"2025-12-04T20:03:00.854Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.medtronic.com/en-us/e/product-security/security-bulletins/carelink-network-vulnerabilities.html"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.5.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-12-08T21:08:39.951215Z","id":"CVE-2025-12995","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-12-08T21:08:48.839Z"}}]}}