{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-12142","assignerOrgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","state":"PUBLISHED","assignerShortName":"ABB","dateReserved":"2025-10-24T10:40:22.394Z","datePublished":"2025-10-29T12:00:42.236Z","dateUpdated":"2025-10-29T13:30:33.090Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Terra AC wallbox","vendor":"ABB","versions":[{"lessThanOrEqual":"1.8.33","status":"affected","version":"0","versionType":"custom"}]}],"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:abb:terra_ac_wallbox:*:*:*:*:*:*:*:*","versionEndIncluding":"1.8.33","versionStartIncluding":"0","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"datePublic":"2025-10-27T04:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.<p>This issue affects Terra AC wallbox: through 1.8.33.</p>"}],"value":"Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33."}],"metrics":[{"cvssV4_0":{"Automatable":"NO","Recovery":"AUTOMATIC","Safety":"NEGLIGIBLE","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"ADJACENT","baseScore":6.9,"baseSeverity":"MEDIUM","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"DIFFUSE","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"LOW"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":6.1,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-120","description":"CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","shortName":"ABB","dateUpdated":"2025-10-29T12:00:42.236Z"},"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8107&LanguageCode=en&DocumentPartId=&Action=Launch"}],"source":{"discovery":"UNKNOWN"},"title":"BSS(Block Started by Symbol) Memory Corruption Vulnerability","x_generator":{"engine":"Vulnogram 0.4.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-10-29T13:25:28.068483Z","id":"CVE-2025-12142","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-10-29T13:30:33.090Z"}}]}}