{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2025-11527","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2025-10-08T19:05:32.826Z","datePublished":"2025-10-09T02:32:13.681Z","dateUpdated":"2026-02-24T06:55:06.629Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2026-02-24T06:55:06.629Z"},"title":"Tenda AC7 fast_setting_pppoe_set stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"Stack-based Buffer Overflow"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-119","lang":"en","description":"Memory Corruption"}]}],"affected":[{"vendor":"Tenda","product":"AC7","versions":[{"version":"15.03.06.44","status":"affected"}],"cpes":["cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*"]}],"descriptions":[{"lang":"en","value":"A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR"}}],"timeline":[{"time":"2025-10-08T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2025-10-08T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2025-10-09T10:44:48.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_miemie (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.327665","name":"VDB-327665 | Tenda AC7 fast_setting_pppoe_set stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.327665","name":"VDB-327665 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.669856","name":"Submit #669856 | Tenda AC7 V15.03.06.44 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/fast_setting_pppoe_set.md","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"references":[{"url":"https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/fast_setting_pppoe_set.md","tags":["exploit"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-10-09T13:30:03.144131Z","id":"CVE-2025-11527","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-10-14T14:17:21.858Z"}}]}}