{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-11123","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2025-09-27T17:51:40.561Z","datePublished":"2025-09-28T22:32:07.327Z","dateUpdated":"2025-09-29T12:05:30.528Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2025-09-28T22:32:07.327Z"},"title":"Tenda AC18 saveAutoQos stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"Stack-based Buffer Overflow"}]},{"descriptions":[{"type":"CWE","cweId":"CWE-119","lang":"en","description":"Memory Corruption"}]}],"affected":[{"vendor":"Tenda","product":"AC18","versions":[{"version":"15.03.05.19","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used."},{"lang":"de","value":"Eine Schwachstelle wurde in Tenda AC18 15.03.05.19 gefunden. Betroffen davon ist ein unbekannter Prozess der Datei /goform/saveAutoQos. Durch Manipulation des Arguments enable mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Die Ausnutzung wurde veröffentlicht und kann verwendet werden."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR"}}],"timeline":[{"time":"2025-09-27T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2025-09-27T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2025-09-27T19:56:52.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_miemie (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.326204","name":"VDB-326204 | Tenda AC18 saveAutoQos stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.326204","name":"VDB-326204 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.664197","name":"Submit #664197 | Tenda AC18 V15.03.05.19(6318) Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC18/saveAutoQos.md","tags":["related"]},{"url":"https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC18/saveAutoQos.md#poc","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-09-29T12:05:21.577069Z","id":"CVE-2025-11123","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-09-29T12:05:30.528Z"}}]}}