{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2025-0477","assignerOrgId":"b73dd486-f505-4403-b634-40b078b177f0","state":"PUBLISHED","assignerShortName":"Rockwell","dateReserved":"2025-01-14T21:25:49.213Z","datePublished":"2025-01-30T17:49:03.933Z","dateUpdated":"2025-02-12T19:51:11.151Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"FactoryTalk® AssetCentre","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"All prior to V15.00.001"}]}],"datePublic":"2025-01-30T17:32:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application.</span>\n\n<br>"}],"value":"An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":9.3,"baseSeverity":"CRITICAL","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-522","description":"CWE-522 Insufficiently Protected Credentials","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"b73dd486-f505-4403-b634-40b078b177f0","shortName":"Rockwell","dateUpdated":"2025-01-30T17:49:03.933Z"},"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1721.html"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<span style=\"background-color: rgb(255, 255, 255);\">Corrected in V15.00.01 and later.</span><br>"}],"value":"Corrected in V15.00.01 and later."}],"source":{"advisory":"SD1721","discovery":"EXTERNAL"},"title":"Rockwell Automation FactoryTalk® AssetCentre Data Exposure Vulnerability","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2025-0477","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2025-01-30T19:46:12.924131Z"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-02-12T19:51:11.151Z"}}]}}