{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-9409","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","state":"PUBLISHED","assignerShortName":"schneider","dateReserved":"2024-10-01T12:08:25.066Z","datePublished":"2024-11-13T04:29:01.040Z","dateUpdated":"2024-11-13T14:43:17.912Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"PowerLogic PM5320","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2.3.8 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic PM5340","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2.3.8 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic PM5341","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2.6.6 and prior"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\n\n<br>"}],"value":"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network."}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-400","description":"CWE-400 Uncontrolled Resource Consumption","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider","dateUpdated":"2024-11-13T04:29:01.040Z"},"references":[{"url":"https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"schneider-electric","product":"powerlogic_pm5320","cpes":["cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"2.3.8","versionType":"custom"}]},{"vendor":"schneider-electric","product":"powerlogic_pm5340","cpes":["cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"2.3.8","versionType":"custom"}]},{"vendor":"schneider-electric","product":"powerlogic_pm5341","cpes":["cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"2.6.6","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-13T14:40:24.630364Z","id":"CVE-2024-9409","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-13T14:43:17.912Z"}}]}}