{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-8224","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-08-27T13:11:58.086Z","datePublished":"2024-08-27T23:00:07.675Z","dateUpdated":"2024-08-28T15:18:02.331Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-08-27T23:00:07.675Z"},"title":"Tenda G3 setDebugCfg formSetDebugCfg stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"G3","versions":[{"version":"15.11.0.20","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.20. This issue affects the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Eine Schwachstelle wurde in Tenda G3 15.11.0.20 entdeckt. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formSetDebugCfg der Datei /goform/setDebugCfg. Durch das Beeinflussen des Arguments enable/level/module mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-08-27T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-08-27T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-08-27T15:17:27.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"wxhwxhwxh_tutu (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.275933","name":"VDB-275933 | Tenda G3 setDebugCfg formSetDebugCfg stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.275933","name":"VDB-275933 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.393999","name":"Submit #393999 | Tenda G3V3.0 V15.11.0.20 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/AHU-IoT-vulnerable/blob/main/Tenda/G3V3.0/formSetDebugCfg.md","tags":["exploit"]},{"url":"https://www.tenda.com.cn/","tags":["product"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"g3_firmware","cpes":["cpe:2.3:o:tenda:g3_firmware:15.11.0.20:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"15.11.0.20","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-28T15:17:51.613655Z","id":"CVE-2024-8224","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-28T15:18:02.331Z"}}]}}