{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-7707","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-08-12T16:13:45.110Z","datePublished":"2024-08-13T00:00:07.511Z","dateUpdated":"2024-08-14T16:11:06.129Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-08-13T00:00:07.511Z"},"title":"Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"FH1206","versions":[{"version":"02.03.01.35","status":"affected"}],"modules":["HTTP POST Request Handler"]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Eine Schwachstelle wurde in Tenda FH1206 02.03.01.35 gefunden. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion formSafeEmailFilter der Datei /goform/SafeEmailFilter der Komponente HTTP POST Request Handler. Durch Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-08-12T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-08-12T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-08-12T18:18:48.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"Yangshuangning (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.274190","name":"VDB-274190 | Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.274190","name":"VDB-274190 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.385670","name":"Submit #385670 | Tenda FH1206 V02.03.01.35 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/VodkaVortex/IoT/blob/main/formSafeEmailFilter.md","tags":["exploit"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"fh1206_firmware","cpes":["cpe:2.3:a:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"02.03.01.35","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-14T16:02:09.859423Z","id":"CVE-2024-7707","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-14T16:11:06.129Z"}}]}}