{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-7614","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-08-08T14:28:35.326Z","datePublished":"2024-08-08T22:31:03.812Z","dateUpdated":"2024-08-15T17:19:10.011Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-08-08T22:31:03.812Z"},"title":"Tenda FH1206 qossetting fromqossetting stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"FH1206","versions":[{"version":"1.2.0.8(8155)","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda FH1206 1.2.0.8(8155). It has been classified as critical. Affected is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Es wurde eine kritische Schwachstelle in Tenda FH1206 1.2.0.8(8155) ausgemacht. Betroffen hiervon ist die Funktion fromqossetting der Datei /goform/qossetting. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-08-08T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-08-08T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-08-08T16:33:44.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"BeaCox (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.273984","name":"VDB-273984 | Tenda FH1206 qossetting fromqossetting stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.273984","name":"VDB-273984 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.383692","name":"Submit #383692 | Tenda FH1206 1.2.0.8 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/BeaCox/IoT_vuln/tree/main/tenda/FH1206/qossetting_bof","tags":["exploit"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"fh1206_firmware","cpes":["cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"1.2.0.8(8155)","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-09T17:25:15.765728Z","id":"CVE-2024-7614","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-15T17:19:10.011Z"}}]}}