{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-7517","assignerOrgId":"87b297d7-335e-4844-9551-11b97995a791","state":"PUBLISHED","assignerShortName":"brocade","dateReserved":"2024-08-05T22:49:54.345Z","datePublished":"2024-11-21T05:53:34.442Z","dateUpdated":"2025-09-09T19:02:20.886Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Fabric OS","vendor":"Brocade","versions":[{"status":"affected","version":"Brocade Fabric OS versions before 9.2.0c, and 9.2.1 through 9.2.1a"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.</p><p>This specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack.</p>"}],"value":"A command injection vulnerability in Brocade Fabric OS before 9.2.0c, and 9.2.1 through 9.2.1a on IP extension platforms could allow a local authenticated attacker to perform a privileged escalation via crafted use of the portcfg command.\n\nThis specific exploitation is only possible on IP Extension platforms: Brocade 7810, Brocade 7840, Brocade 7850 and on Brocade X6 or X7 directors with an SX-6 Extension blade installed. The attacker must be logged into the switch via SSH or serial console to conduct the attack."}],"impacts":[{"capecId":"CAPEC-248","descriptions":[{"lang":"en","value":"CAPEC-248 Command Injection"}]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","baseScore":8.5,"baseSeverity":"HIGH","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"87b297d7-335e-4844-9551-11b97995a791","shortName":"brocade","dateUpdated":"2025-09-09T19:02:20.886Z"},"references":[{"url":"https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25071"}],"source":{"discovery":"UNKNOWN"},"title":"Privileged escalation via crafted use of portcfg command","x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"brocade","product":"fabric_os","cpes":["cpe:2.3:o:brocade:fabric_os:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"9.2.0c","versionType":"custom"},{"version":"9.2.1","status":"affected","lessThan":"9.2.1a","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-21T14:02:36.321972Z","id":"CVE-2024-7517","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-21T17:52:58.535Z"}}]}}