{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-7335","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-07-31T12:30:18.894Z","datePublished":"2024-08-01T02:00:06.560Z","dateUpdated":"2024-08-06T19:39:28.167Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-08-01T02:00:06.560Z"},"title":"TOTOLINK EX200 getSaveConfig buffer overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-120","lang":"en","description":"CWE-120 Buffer Overflow"}]}],"affected":[{"vendor":"TOTOLINK","product":"EX200","versions":[{"version":"4.0.3c.7646_B20201211","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability classified as critical has been found in TOTOLINK EX200 4.0.3c.7646_B20201211. Affected is the function getSaveConfig of the file /cgi-bin/cstecgi.cgi?action=save&setting. The manipulation of the argument http_host leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-273258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Es wurde eine kritische Schwachstelle in TOTOLINK EX200 4.0.3c.7646_B20201211 entdeckt. Dabei betrifft es die Funktion getSaveConfig der Datei /cgi-bin/cstecgi.cgi?action=save&setting. Durch das Manipulieren des Arguments http_host mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-07-31T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-07-31T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-07-31T14:35:41.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_tu (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.273258","name":"VDB-273258 | TOTOLINK EX200 getSaveConfig buffer overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.273258","name":"VDB-273258 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.379313","name":"Submit #379313 | TOTOLINK EX200 V4.0.3c.7646_B20201211 buffer overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/EX200/getSaveConfig.md","tags":["exploit"]}]},"adp":[{"affected":[{"vendor":"totolink","product":"ex200_firmware","cpes":["cpe:2.3:o:totolink:ex200_firmware:4.0.3c.7646_b20201211:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"4.0.3c.7646_b20201211","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-06T19:38:43.936600Z","id":"CVE-2024-7335","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-06T19:39:28.167Z"}}]}}