{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-6962","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-07-21T13:27:25.259Z","datePublished":"2024-07-21T23:31:04.452Z","dateUpdated":"2024-08-01T21:45:38.401Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-07-21T23:31:04.452Z"},"title":"Tenda O3 formQosSet stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"O3","versions":[{"version":"1.0.0.10","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"In Tenda O3 1.0.0.10 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Das betrifft die Funktion formQosSet. Durch das Beeinflussen des Arguments remark/ipRange/upSpeed/downSpeed/enable mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-07-21T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-07-21T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-07-21T15:32:40.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_tu (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.272116","name":"VDB-272116 | Tenda O3 formQosSet stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.272116","name":"VDB-272116 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.374583","name":"Submit #374583 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/formQosSet.md","tags":["exploit"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"o3v2","cpes":["cpe:2.3:h:tenda:o3v2:1.0.0.10:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"1.0.0.10","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-22T16:53:25.462408Z","id":"CVE-2024-6962","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-22T16:58:20.539Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T21:45:38.401Z"},"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.272116","name":"VDB-272116 | Tenda O3 formQosSet stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.272116","name":"VDB-272116 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.374583","name":"Submit #374583 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/formQosSet.md","tags":["exploit","x_transferred"]}]}]}}