{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-6189","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-06-20T05:38:53.981Z","datePublished":"2024-06-20T14:00:05.817Z","dateUpdated":"2024-08-01T21:33:05.173Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-06-20T14:00:05.817Z"},"title":"Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"A301","versions":[{"version":"15.13.08.12","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Es wurde eine kritische Schwachstelle in Tenda A301 15.13.08.12 ausgemacht. Es betrifft die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Dank Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV4_0":{"version":"4.0","baseScore":8.7,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseSeverity":"HIGH"}},{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-06-20T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-06-20T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-06-20T07:44:13.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"seuilping (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.269160","name":"VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.269160","name":"VDB-269160 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.355264","name":"Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd","tags":["exploit"]}]},"adp":[{"affected":[{"vendor":"tenda","product":"a301","cpes":["cpe:2.3:h:tenda:a301:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"15.13.08.12","status":"affected"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-06-25T15:32:07.042197Z","id":"CVE-2024-6189","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-25T15:40:00.073Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T21:33:05.173Z"},"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.269160","name":"VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.269160","name":"VDB-269160 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.355264","name":"Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd","tags":["exploit","x_transferred"]}]}]}}