{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-52566","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-11-14T12:25:53.335Z","datePublished":"2024-11-18T15:39:25.382Z","dateUpdated":"2024-12-10T13:54:00.271Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-12-10T13:54:00.271Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24233)"}],"affected":[{"vendor":"Siemens","product":"Teamcenter Visualization V14.2","versions":[{"status":"affected","version":"0","lessThan":"V14.2.0.14","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V14.3","versions":[{"status":"affected","version":"0","lessThan":"V14.3.0.12","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2312","versions":[{"status":"affected","version":"0","lessThan":"V2312.0008","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Teamcenter Visualization V2406","versions":[{"status":"affected","version":"0","lessThan":"V2406.0005","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2302","versions":[{"status":"affected","version":"0","lessThan":"V2302.0018","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Tecnomatix Plant Simulation V2404","versions":[{"status":"affected","version":"0","lessThan":"V2404.0007","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":7.3,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-787","description":"CWE-787: Out-of-bounds Write","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-824503.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-645131.html"}]},"adp":[{"affected":[{"vendor":"siemens","product":"tecnomatix_plant_simulation","cpes":["cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"V2302.0018","versionType":"custom"},{"version":"0","status":"affected","lessThan":"V2404.0007","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-18T19:50:45.809688Z","id":"CVE-2024-52566","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-18T19:51:41.469Z"}}]}}