{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-50572","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-10-24T13:47:50.881Z","datePublished":"2024-11-12T12:50:08.911Z","dateUpdated":"2025-02-11T10:28:50.351Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2025-02-11T10:28:50.351Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell."}],"affected":[{"vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) EU","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"RUGGEDCOM RM1224 LTE(4G) NAM","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M804PB","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M812-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M816-1 ADSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M826-2 SHDSL-Router","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M874-2","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M874-3","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M874-3 3G-Router (CN)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-3","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-3 (ROK)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-4","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-4 (EU)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M876-4 (NAM)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM853-1 (A1)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM853-1 (B1)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM853-1 (EU)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (A1)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (B1)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (CN)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (EU)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE MUM856-1 (RoW)","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE S615 EEC LAN-Router","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE S615 LAN-Router","versions":[{"status":"affected","version":"0","lessThan":"V8.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAB762-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM763-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM763-1 (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM763-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUB762-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUB762-1 iFeatures","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM763-1 (US)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM766-1","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM766-1 (ME)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE WUM766-1 (USA)","versions":[{"status":"affected","version":"0","lessThan":"V3.0.0","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","baseScore":8.6,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-74","description":"CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-354112.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-769027.html"}]},"adp":[{"affected":[{"vendor":"siemens","product":"scalance_m874-3_firmware","cpes":["cpe:2.3:o:siemens:scalance_m874-3_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_m816-1_\\(annex_b\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_m816-1_\\(annex_a\\)_firmware:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_m816-1_\\(annex_b\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_s615_firmware","cpes":["cpe:2.3:o:siemens:scalance_s615_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_s615_eec_firmware","cpes":["cpe:2.3:o:siemens:scalance_s615_eec_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum856-1_\\(row\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum856-1_\\(row\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum856-1_\\(eu\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum856-1_\\(eu\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum856-1_\\(cn\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum856-1_\\(cn\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum856-1_\\(b1\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum856-1_\\(b1\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum856-1_\\(a1\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum856-1_\\(a1\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum853-1_\\(a1\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum853-1_\\(a1\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum853-1_\\(b1\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum853-1_\\(b1\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_mum853-1_\\(eu\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_mum853-1_\\(eu\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_m876-4_firmware","cpes":["cpe:2.3:o:siemens:scalance_m876-4_\\(eu\\)_firmware:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_m876-4_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_m876-3_firmware","cpes":["cpe:2.3:o:siemens:scalance_m876-3_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_m812-1_\\(annex_b\\)_firmware","cpes":["cpe:2.3:o:siemens:scalance_m812-1_\\(annex_a\\)_firmware:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:scalance_m812-1_\\(annex_b\\)_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"scalance_m804pb_firmware","cpes":["cpe:2.3:o:siemens:scalance_m804pb_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]},{"vendor":"siemens","product":"ruggedcom_rm1224_lte\\(4g\\)_nam_firmware","cpes":["cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu_firmware:-:*:*:*:*:*:*:*","cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"8.2","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-20T16:51:10.879106Z","id":"CVE-2024-50572","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-20T16:51:19.040Z"}}]}}