{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-4548","assignerOrgId":"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be","state":"PUBLISHED","assignerShortName":"tenable","dateReserved":"2024-05-06T13:35:43.319Z","datePublished":"2024-05-06T13:51:07.049Z","dateUpdated":"2024-08-01T20:47:40.056Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"DIAEnergie","vendor":"Delta Electronics","versions":[{"lessThanOrEqual":"1.10.1.8610","status":"affected","version":"0","versionType":"custom"}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An SQLi vulnerability exists in&nbsp;Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field."}],"value":"An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field."}],"impacts":[{"capecId":"CAPEC-66","descriptions":[{"lang":"en","value":"CAPEC-66 SQL Injection"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-20","description":"CWE-20 Improper Input Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"5ac1ecc2-367a-4d16-a0b2-35d495ddd0be","shortName":"tenable","dateUpdated":"2024-05-06T13:51:07.049Z"},"references":[{"url":"https://www.tenable.com/security/research/tra-2024-13"}],"source":{"discovery":"UNKNOWN"},"title":"Delta Electronics DIAEnergie SQL Injection","x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"affected":[{"vendor":"deltaww","product":"diaenergie","cpes":["cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThanOrEqual":"1.10.1.8610","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-05-13T13:41:00.312856Z","id":"CVE-2024-4548","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-20T20:06:39.622Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T20:47:40.056Z"},"title":"CVE Program Container","references":[{"url":"https://www.tenable.com/security/research/tra-2024-13","tags":["x_transferred"]}]}]}}