{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-4497","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-05-04T07:22:55.421Z","datePublished":"2024-05-05T06:31:04.218Z","dateUpdated":"2024-08-01T20:40:47.441Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-05-05T06:31:04.218Z"},"title":"Tenda i21 formexeCommand stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"i21","versions":[{"version":"1.0.0.14(4656)","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"In Tenda i21 1.0.0.14(4656) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion formexeCommand. Durch Beeinflussen des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-05-04T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-05-04T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-05-04T09:28:18.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_miemie (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.263086","name":"VDB-263086 | Tenda i21 formexeCommand stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.263086","name":"VDB-263086 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.323607","name":"Submit #323607 | Tenda i21 V1.0.0.14(4656) Buffer Overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formexeCommand.md","tags":["exploit"]}]},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-4497","role":"CISA Coordinator","options":[{"Exploitation":"poc"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2024-05-13T17:30:23.578110Z"}}}],"affected":[{"cpes":["cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*"],"vendor":"tenda","product":"i21","versions":[{"status":"affected","version":"1.0.0.14(4656)"}],"defaultStatus":"unknown"}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T17:54:14.378Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T20:40:47.441Z"},"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.263086","name":"VDB-263086 | Tenda i21 formexeCommand stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.263086","name":"VDB-263086 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.323607","name":"Submit #323607 | Tenda i21 V1.0.0.14(4656) Buffer Overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formexeCommand.md","tags":["exploit","x_transferred"]}]}]}}