{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-44102","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","state":"PUBLISHED","assignerShortName":"siemens","dateReserved":"2024-08-20T06:28:50.265Z","datePublished":"2024-11-12T12:49:33.464Z","dateUpdated":"2024-11-15T19:24:48.170Z"},"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-11-12T12:49:33.464Z"},"descriptions":[{"lang":"en","value":"A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges."}],"affected":[{"vendor":"Siemens","product":"PP TeleControl Server Basic 1000 to 5000 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"PP TeleControl Server Basic 256 to 1000 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"PP TeleControl Server Basic 32 to 64 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"PP TeleControl Server Basic 64 to 256 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"PP TeleControl Server Basic 8 to 32 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic 1000 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic 256 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic 32 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic 5000 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic 64 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic 8 V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic Serv Upgr","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"TeleControl Server Basic Upgr V3.1","versions":[{"status":"affected","version":"0","lessThan":"V3.1.2.1","versionType":"custom"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","baseScore":10,"baseSeverity":"CRITICAL"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","baseScore":10,"baseSeverity":"CRITICAL"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-502","description":"CWE-502: Deserialization of Untrusted Data","type":"CWE"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-454789.html"}]},"adp":[{"affected":[{"vendor":"siemens","product":"telecontrol_server_basic","cpes":["cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"3.1.2.1","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-11-15T19:24:38.461958Z","id":"CVE-2024-44102","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-11-15T19:24:48.170Z"}}]}}