{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-4065","assignerOrgId":"1af790b2-7ee1-4545-860a-a788eba489b5","state":"PUBLISHED","assignerShortName":"VulDB","dateReserved":"2024-04-23T13:22:21.928Z","datePublished":"2024-04-23T20:00:07.093Z","dateUpdated":"2024-08-01T20:26:57.322Z"},"containers":{"cna":{"providerMetadata":{"orgId":"1af790b2-7ee1-4545-860a-a788eba489b5","shortName":"VulDB","dateUpdated":"2024-04-23T20:00:07.093Z"},"title":"Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow","problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-121","lang":"en","description":"CWE-121 Stack-based Buffer Overflow"}]}],"affected":[{"vendor":"Tenda","product":"AC8","versions":[{"version":"16.03.34.09","status":"affected"}]}],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"de","value":"Eine Schwachstelle wurde in Tenda AC8 16.03.34.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetRebootTimer der Datei /goform/SetRebootTimer. Mit der Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden. Der Exploit steht zur öffentlichen Verfügung."}],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":8.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV3_0":{"version":"3.0","baseScore":8.8,"vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseSeverity":"HIGH"}},{"cvssV2_0":{"version":"2.0","baseScore":9,"vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C"}}],"timeline":[{"time":"2024-04-23T00:00:00.000Z","lang":"en","value":"Advisory disclosed"},{"time":"2024-04-23T02:00:00.000Z","lang":"en","value":"VulDB entry created"},{"time":"2024-04-23T15:27:31.000Z","lang":"en","value":"VulDB entry last update"}],"credits":[{"lang":"en","value":"yhryhryhr_tu (VulDB User)","type":"reporter"}],"references":[{"url":"https://vuldb.com/?id.261791","name":"VDB-261791 | Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/?ctiid.261791","name":"VDB-261791 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/?submit.316494","name":"Submit #316494 | Tenda AC8v4 V16.03.34.09 buffer overflow","tags":["third-party-advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md","tags":["exploit"]}]},"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2024-4065","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2024-04-24T14:33:54.863413Z"}}}],"affected":[{"cpes":["cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*"],"vendor":"tenda","product":"ac8","versions":[{"status":"affected","version":"-"}],"defaultStatus":"unknown"}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-06-04T17:53:56.992Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T20:26:57.322Z"},"title":"CVE Program Container","references":[{"url":"https://vuldb.com/?id.261791","name":"VDB-261791 | Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow","tags":["vdb-entry","technical-description","x_transferred"]},{"url":"https://vuldb.com/?ctiid.261791","name":"VDB-261791 | CTI Indicators (IOB, IOC, IOA)","tags":["signature","permissions-required","x_transferred"]},{"url":"https://vuldb.com/?submit.316494","name":"Submit #316494 | Tenda AC8v4 V16.03.34.09 buffer overflow","tags":["third-party-advisory","x_transferred"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md","tags":["exploit","x_transferred"]}]}]}}