{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-39576","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","state":"PUBLISHED","assignerShortName":"dell","dateReserved":"2024-06-26T02:14:30.866Z","datePublished":"2024-08-22T02:54:05.865Z","dateUpdated":"2024-08-22T13:39:02.079Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Dell Power Manager (DPM)","vendor":"Dell","versions":[{"lessThan":"3.16.0","status":"affected","version":"N/A","versionType":"semver"}]}],"credits":[{"lang":"en","type":"finder","value":"Dell would like to thank Lefteris Panos from LRQA Nettitude for reporting this issue"}],"datePublic":"2024-08-21T06:30:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges."}],"value":"Dell Power Manager (DPM), versions 3.15.0 and prior, contains an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-266","description":"CWE-266: Incorrect Privilege Assignment","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"c550e75a-17ff-4988-97f0-544cde3820fe","shortName":"dell","dateUpdated":"2024-08-22T02:54:05.865Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.dell.com/support/kbdoc/en-us/000227010/dsa-2024-323"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"dell","product":"power_manager","cpes":["cpe:2.3:a:dell:power_manager:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"3.16.0","versionType":"semver"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-08-22T13:35:22.576186Z","id":"CVE-2024-39576","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-08-22T13:39:02.079Z"}}]}}