{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-39530","assignerOrgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","state":"PUBLISHED","assignerShortName":"juniper","dateReserved":"2024-06-25T15:12:53.240Z","datePublished":"2024-07-11T16:04:13.075Z","dateUpdated":"2024-08-02T04:26:15.620Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"Junos OS","vendor":"Juniper Networks","versions":[{"lessThan":"21.4R3-S5","status":"affected","version":"21.4R3","versionType":"semver"},{"lessThan":"22.1R3-S4","status":"affected","version":"22.1R3","versionType":"semver"},{"lessThan":"22.2R3","status":"affected","version":"22.2R2","versionType":"semver"},{"lessThan":"22.3R2-S2, 22.3R3","status":"affected","version":"22.3R1","versionType":"semver"},{"lessThan":"22.4R2","status":"affected","version":"22.4R1","versionType":"semver"},{"lessThan":"21.4","status":"unaffected","version":"0","versionType":"semver"}]}],"configurations":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"For this issue to be exploited over GRPC it needs to be configured as follows:<br><br><tt>[ system services extension-service request-response grpc ]</tt>"}],"value":"For this issue to be exploited over GRPC it needs to be configured as follows:\n\n[ system services extension-service request-response grpc ]"}],"datePublic":"2024-07-10T16:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis management daemon (chassisd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause a \n\n<span style=\"background-color: rgb(255, 255, 255);\">Denial-of-Service (DoS)</span>.<br><br>If an attempt is made to access specific sensors on platforms not supporting these sensors, either via GRPC or netconf, chassisd will crash and restart leading to a restart of all FPCs and thereby a complete outage.<br><br><p>This issue affects Junos OS:</p><p></p><ul><li>21.4 versions from 21.4R3 before 21.4R3-S5,</li><li>22.1 versions from 22.1R3 before 22.1R3-S4,</li><li>22.2 versions from 22.2R2 before 22.2R3,</li><li>22.3 versions from 22.3R1 before 22.3R2-S2, 22.3R3,</li><li>22.4 versions from 22.4R1 before 22.4R2.</li></ul>This issue does not affect Junos OS versions earlier than 21.4.<br>"}],"value":"An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis management daemon (chassisd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause a \n\nDenial-of-Service (DoS).\n\nIf an attempt is made to access specific sensors on platforms not supporting these sensors, either via GRPC or netconf, chassisd will crash and restart leading to a restart of all FPCs and thereby a complete outage.\n\nThis issue affects Junos OS:\n\n\n\n  *  21.4 versions from 21.4R3 before 21.4R3-S5,\n  *  22.1 versions from 22.1R3 before 22.1R3-S4,\n  *  22.2 versions from 22.2R2 before 22.2R3,\n  *  22.3 versions from 22.3R1 before 22.3R2-S2, 22.3R3,\n  *  22.4 versions from 22.4R1 before 22.4R2.\n\n\nThis issue does not affect Junos OS versions earlier than 21.4."}],"exploits":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"value":"Juniper SIRT is not aware of any malicious exploitation of this vulnerability."}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]},{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.7,"baseSeverity":"HIGH","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-754","description":"CWE-754 Improper Check for Unusual or Exceptional Conditions","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"8cbe9d5a-a066-4c94-8978-4b15efeae968","shortName":"juniper","dateUpdated":"2024-07-11T16:04:13.075Z"},"references":[{"tags":["vendor-advisory"],"url":"https://supportportal.juniper.net/JSA82989"}],"solutions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"The following software releases have been updated to resolve this specific issue: 21.4R3-S5, 22.1R3-S4, 22.2R3, 22.3R2-S2, 22.3R3, 22.4R2, 23.2R1, and all subsequent releases."}],"value":"The following software releases have been updated to resolve this specific issue: 21.4R3-S5, 22.1R3-S4, 22.2R3, 22.3R2-S2, 22.3R3, 22.4R2, 23.2R1, and all subsequent releases."}],"source":{"advisory":"JSA82989","defect":["1708557"],"discovery":"INTERNAL"},"title":"Junos OS: Attempting to access specific sensors on platforms not supporting these will lead to a chassisd crash","workarounds":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"There are no known workarounds for this issue."}],"value":"There are no known workarounds for this issue."}],"x_generator":{"engine":"Vulnogram 0.1.0-dev"}},"adp":[{"affected":[{"vendor":"juniper","product":"junos_os","cpes":["cpe:2.3:o:juniper:junos_os:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"21.4","versionType":"semver"},{"version":"22.4r1","status":"affected","lessThan":"22.4r2","versionType":"semver"},{"version":"22.3r1","status":"affected","lessThan":"22.3r2-s2","versionType":"semver"},{"version":"22.3r1","status":"affected","lessThan":"22.3r3","versionType":"custom"},{"version":"22.2r2","status":"affected","lessThan":"22.2r3","versionType":"semver"},{"version":"22.1r3","status":"affected","lessThan":"22.1r3-s4","versionType":"semver"},{"version":"21.4r3","status":"affected","lessThan":"21.4r3-s5","versionType":"semver"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-11T20:25:07.250062Z","id":"CVE-2024-39530","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-12T16:31:27.051Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-02T04:26:15.620Z"},"title":"CVE Program Container","references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://supportportal.juniper.net/JSA82989"}]}]}}