{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2024-3904","assignerOrgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","state":"PUBLISHED","assignerShortName":"Mitsubishi","dateReserved":"2024-04-17T02:56:01.539Z","datePublished":"2024-07-04T09:11:22.679Z","dateUpdated":"2024-08-01T20:26:57.118Z"},"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"MELIPC Series MI5122-VW","vendor":"Mitsubishi Electric Corporation","versions":[{"status":"affected","version":"Firmware versions \"05\" to \"07\""}]}],"descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions \"05\" to \"07\" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product."}],"value":"Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions \"05\" to \"07\" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product."}],"impacts":[{"descriptions":[{"lang":"en","value":"Malicious Code Execution"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-276","description":"CWE-276 Incorrect Default Permissions","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"e0f77b61-78fd-4786-b3fb-1ee347a748ad","shortName":"Mitsubishi","dateUpdated":"2024-07-23T00:28:13.328Z"},"references":[{"tags":["vendor-advisory"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf"},{"tags":["government-resource"],"url":"https://jvn.jp/vu/JVNVU91215350/index.html"},{"tags":["government-resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"}},"adp":[{"affected":[{"vendor":"mitsubishi","product":"melipc_mi5122-vw_firmware","cpes":["cpe:2.3:o:mitsubishi:melipc_mi5122-vw_firmware:05:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","versions":[{"version":"05","status":"affected","lessThanOrEqual":"07","versionType":"custom"}]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-05T13:49:41.501811Z","id":"CVE-2024-3904","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-05T13:52:40.732Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-01T20:26:57.118Z"},"title":"CVE Program Container","references":[{"tags":["vendor-advisory","x_transferred"],"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf"},{"tags":["government-resource","x_transferred"],"url":"https://jvn.jp/vu/JVNVU91215350/index.html"},{"tags":["government-resource","x_transferred"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-02"}]}]}}